039686 美國戴安Dionex CarboPac PA1 Carbohydrate Column 生物色譜柱
如果您對該產品感興趣的話,可以
產品名稱: 039686 美國戴安Dionex CarboPac PA1 Carbohydrate Column 生物色譜柱
產品型號: 039686
產品展商: 戴安Dionex
產品文檔: 無相關文檔
簡單介紹
戴安公司生產的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術優勢和方法已廣泛地應用于各個領域,其市場占有率達80%。全球與離子色譜相關的文章有90%均出自戴安公司生產的離子色譜儀。
戴安公司的快速溶劑萃取儀15分鐘之內僅用15毫升溶劑既可完成對10g樣品的萃取,該技術已在環境、**、食品和聚合物工業等領域得到廣泛應用。
039686 美國戴安Dionex CarboPac PA1 Carbohydrate Column 生物色譜柱
的詳細介紹
Ideal Column for the Separation of Neutral and Acidic Monosaccharides
The CarboPac® PA1 is an anion-exchange column for the separation of mono-,
disaccharides, and specific oligosaccharides using an isocratic eluent.
Sialic acid analysis has also been demonstrated on this column.
-
General-purpose column for isocratic determination of monosaccharides and disaccharides
-
Detection by pulsed amperometric detection; no derivatization needed
-
Approved for use in a variety of official methods for the analysis of foods
The unique MicroBead? pellicular structure of the CarboPac PA1 resin gives it stability from
pH 0–14 at all concentrations of buffer salts. The pellicular resin
structure allows excellent mass transfer resulting in fast gradient
reequilibration.
The CarboPac PA1 column is used with pulsed
amperometric detection; no derivatization is required. Sensitivity on
the PA1 is not as high as with the CarboPac PA20 or PA10 for
monosaccharide analysis. Thus the CarboPac PA1 is well suited for the
analysis of foods for nutritional labeling. The CarboPac PA1 has been
approved for use in a number of official methods.
CarboPac PA1 Column for Routine Carbohydrate Analysis Specifications
|
Dimensions
|
CarboPac PA1 Analytical Column:
4 × 250 mm and 2 × 250 mm
CarboPac PA1 Guard Column:
4 × 50 mm and 2 × 50 mm
CarboPac PA1 Semipreparative Column:
22 × 250 mm
|
Maximum operating pressure
|
4000 psi (27.9 MPa)
|
Temperature range
|
4–55 °C
Recommended operating temperature: ambient
|
Typical operating conditions
|
1500 psi at 1.0 mL/min (analytical and guard columns)
Recommended flow rate: 1.0 mL/min (for 4 × 250 mm)
|
Mobile phase compatibility
|
pH 0–14; up to 2% of common HPLC solvents.
Acetate or hydroxide eluents only.
|
Resin composition
|
10-μm-diameter
substrate (polystyrene 2% cross-linked with divinylbenzene)
agglomerated with 500-nm MicroBead quaternary ammonium functionalized
latex (5% cross-linked).
|
Anion-exchange capacity
|
Approximately 100 μeq/column (4 × 250 mm analytical column)
|
Column construction
|
PEEK with 10-32 threaded-ferrule-style end fittings.
All components are nonmetallic.
|
Analytical Columns
|
CarboPac PA1 Analytical Column (2 x 250 mm)
|
057178
|
CarboPac PA1 Analytical Column (4 X 250 mm)
|
035391
|
CarboPac PA1 Semi-Preparative Column (9 x 250 mm)
|
039686
|
CarboPac PA1 Semi-Preparative Column (22 x 250 mm)
|
SP2866
|
Guard Columns
|
CarboPac PA1 Guard Column (2 x 50 mm)
|
057179
|
CarboPac PA1 Guard Column (4 x 50 mm)
|
043096
|
CarboPac PA1 Guard (9 x 50 mm)
|
063501
|