jjbnok.cn-日韩Av无码中文字幕,国产在线aaa片一区二区99,国产精品毛片无遮挡高清,麻豆国产精品va在线观看不卡

  • 1
產品資料

美國戴安Dionex GlycanPac AXR-1 Column 088135 GlycanPac系列生物色譜柱

如果您對該產品感興趣的話,可以
產品名稱: 美國戴安Dionex GlycanPac AXR-1 Column 088135 GlycanPac系列生物色譜柱
產品型號: 088135
產品展商: 戴安Dionex
產品文檔: 無相關文檔

簡單介紹

戴安公司生產的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術優勢和方法已廣泛地應用于各個領域,其市場占有率達80%。全球與離子色譜相關的文章有90%均出自戴安公司生產的離子色譜儀。   戴安公司的快速溶劑萃取儀15分鐘之內僅用15毫升溶劑既可完成對10g樣品的萃取,該技術已在環境、**、食品和聚合物工業等領域得到廣泛應用。


美國戴安Dionex GlycanPac AXR-1 Column 088135 GlycanPac系列生物色譜柱  的詳細介紹

GlycanPac AXR-1 Glycan Analysis Column

GlycanPac AXR-1 Columns for the High-Resolution Separation and Analysis of Glycans

The Thermo Scientific? GlycanPac? AXR-1 column is a high-performance, silica-based HPLC column for the simultaneous separation of glycans by charge, isomerism, and size. It is designed to provide industry-leading resolution with unique selectivities for biologically important glycans, either labeled or native, using either fluorescence and/or mass spectrometry (MS) detection.

Features:

? Unique glycan selectivity based on charge, branch/linkage isomerism, and size
? Exceptional resolution for either native or derivatized glycans
? Utility for both high-resolution glycan structural characterization and glycan quantification
? Compatibility with both MS and fluorescence detection methods
? Reliable column performance
? Available in HPLC (3 μm) and UHPLC (1.9 μm) formats.

The GlycanPac AXR-1 column, based on innovative, mixed-mode surface chemistry, combines both weak anion-exchange (WAX) and reversed-phase interaction mechanisms to produce exceptional glycan selectivity and industry-leading resolution. The WAX functionality provides retention of negatively charged glycans that elute in order of increasing charge, and the reversed-phase mode facilitates resolution of glycans of the same charge according to their isomerism and size. These attributes produce unparalleled glycan separations. The GlycanPac AXR-1 column is designed for HPLC and UHPLC methods using either fluorescence or MS detection, and uses volatile aqueous buffers (e.g., ammonium acetate or ammonium formate) and acetonitrile, presenting the eluting glycans ready for introduction into MS instruments.

GlycanPac AXR-1 columns are based on high-purity and spherical silica substrates in both 1.9 and 3 μm sizes for UHPLC and standard HPLC applications, respectively. GlycanPac AXR-1 columns are available in various dimensions for applications with different resolutions, throughput, and instrument requirements.

GlycanPac AXR-1 Column Specifications
Column Dimensions

1.9 μm: 2.1 × 250mm, 2.1 × 150mm

3 μm: 4.6 × 150mm, 3.0 × 150mm, 2.1 × 150mm

Particle Size Spherical 1.9 μm, 3 μm particles
Substrate High-purity, Porous, Spherical Silica
Surface Area 220 m2/g
Pore size 175 ?
Functional Group WAX and RP Mixed-Mode
Recommended Flow Rate Range:

1.9 μm: 0.2 to 0.4 mL/min. for: all 2.1 mm columns

3 μm: 0.8 to 1.2 ml/min for 4.6 × 150 mm

          0.3 to 0.6 ml/min for 3.0 × 150 mm

          0.1 to 0.3 ml/min. for 2.1 × 150 mm

Pressure Limit

1.9 μm: 10,000 psi for 2.1 ×150mm

             15,000 psi for 2.1 × 250mm

3 μm: 6,000 psi for all 3 μm columns

Temperature Range: Ambient to < 60  oC
pH Range 2.0 - 8.0


Analytical Columns
GlycanPac AXR-1, Analytical, 1.9μm, 2.1x150mm 088136
GlycanPac AXR-1, Analytical, 1.9μm, 2.1x250mm 088135
GlycanPac AXR-1, Analytical, 3.0μm, 2.1x150mm 088251
GlycanPac AXR-1, Analytical, 3.0μm, 3.0x150mm 088252
GlycanPac AXR-1, Analytical, 3.0μm, 4.6 x150mm 088255
Guard Columns
GlycanPac AXR-1, Guard, 3.0μm, 2.1 x10mm,2EA 088258
GlycanPac AXR-1, Guard, 3.0μm, 3.0 x10mm,2EA 088259
GlycanPac AXR-1, Guard, 3.0μm, 4.6 x10mm,2EA 088260
Acclaim SST Guard Cartridge Holder V-2 069580
Acclaim Guard Kit (Holder and coupler) V-2 069707
Guard to Analytical Column Coupler V-2 074188

產品留言
標題
聯系人
聯系電話
內容
驗證碼
點擊換一張
注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發送信息!
2.如有必要,請您留下您的詳細聯系方式!

滬公網安備 31011702004544號